AI summary
Trust: medium
Third-party lab
Janoshik tested this retatrutide batch at 99.526% purity via HPLC. The tested quantity was 21.88 mg, showing a 9.4% deviation from the 20 mg label. Endotoxin status is unknown. The test is older (6-12 months), but customers can cross-check on the lab's public verification URL.
Watch out for
- no endotoxin test
- older (6-12 months)
- quantity deviation (9.4%)
Test date
2025-06-24
Purity
99.53%
Batch / lot
—
Lab
Janoshik
Quantity
label
20 mg
tested
21.88 mg
Qty vs label
+9.4%
Endotoxins
—
Test score
—
Manufacturer
SPB
Certificate
Test report image
Certificate scan as published.
Source
Janoshik (public)
✓ Artifact capturedWe have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.
Verify on upstream- Method
- HPLC
- Test type
- purity+quantity
- Catalogued
- 2026-04-22
- Artifact hash
0317533495a11c31…
This COA is part of TitrateLab's community-trust corpus.
See more from SPB
or learn how trust scores are computed on the