CJC-1295 40.1% Purity — Sry LabsCertificate of Analysis · Independent third-party lab result
LabE tested this CJC-1295 batch at 40.15% purity using HPLC and mass quantification. The quantity tested was 0mg against a 5mg label, indicating a significant deviation. Endotoxin status is unknown. The test is older (6-12 months). Customers can cross-check on the lab's public verification URL.
- very low purity (40.15%)
- 100% quantity deviation
- no endotoxin test
- Test date
- 2025-06-10
- Testing lab
- LabE
- Batch / lot
- (no batch ID)
- Quantity
- 0mg
- Endotoxins
- —
- Assay method
- HPLC + mass quantification + endotoxins
- Test score
- 0.4
- Label dose
- 5mg
How this result compares
This CJC-1295 certificate's tested purity of 40.15% ranks higher than 4% of the 713 CJC-1295 certificates with a purity result we have catalogued (median 99.55%).
Tested 2025-06-10 by LabE via HPLC + mass quantification + endotoxins. This test is newer than 27% of our catalogued CJC-1295 certificates.
Sry Labs has 395 certificates in our corpus, including 4 for CJC-1295 at a median tested purity of 88.03%.
Test report image
Finnrick
Artifact capturedWe have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact shown here.
Verify on the upstream labSaved source document
sha256:6ca720ac225d9aa4…
— immutable copy held by TitrateLab