AI summary
Trust: medium
Third-party lab
LabB tested this CJC-1295 batch (NDAC10N110624) at 98.54% purity via HPLC. The tested quantity was 12.68mg against a 10mg label, a deviation of 26.8%. Endotoxin status is unknown. This test is stale (over 1 year old). Customers can cross-check on the lab's public verification URL.
Watch out for
- stale (1+ years old)
- no endotoxin test
- quantity deviation (26.8%)
Test date
2025-03-20
Purity
98.54%
98.54%
Batch / lot
NDAC10N110624
Lab
LabB
Quantity
label
10mg
tested
12.68mg
Qty vs label
+26.8%
Endotoxins
—
Test score
4.5
Manufacturer
Paramount Peptides
Certificate
Test report image
Certificate scan as published.
Source
Finnrick
✓ Artifact capturedWe have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.
Verify on upstream- Method
- HPLC + mass quantification + endotoxins
- Test type
- finnrick_composite
- Dose
- 10mg
- Container
- Blue Label / Silver Crimp / White Cap
- Catalogued
- 2026-04-16
- Artifact hash
0e6670ed34b25890…
This COA is part of TitrateLab's community-trust corpus.
See more from Paramount Peptides
or learn how trust scores are computed on the
methodology page.