AI summary
Trust: medium
Third-party lab
LabD tested this CJC-1295 batch (HDAC-0002) at 99.13% purity via HPLC. The tested quantity was 12.6mg against a 10mg label, a 26% deviation. Endotoxin status is unknown. The test is older (6-12 months). Customers can cross-check on the lab's public verification URL.
Watch out for
- high quantity deviation
- no endotoxin test
- older (6-12 months)
Test date
2025-05-20
Purity
99.13%
99.13%
Batch / lot
HDAC-0002
Lab
LabD
Quantity
label
10mg
tested
12.6mg
Qty vs label
+26.0%
Endotoxins
—
Test score
5.2
Manufacturer
Paramount Peptides
Certificate
Test report image
Certificate scan as published.
Source
Finnrick
✓ Artifact capturedWe have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.
Verify on upstream- Method
- HPLC + mass quantification + endotoxins
- Test type
- finnrick_composite
- Dose
- 10mg
- Container
- Black Label / Silver Crimp / Black Cap
- Catalogued
- 2026-04-16
- Artifact hash
e7060157ec2c838e…
This COA is part of TitrateLab's community-trust corpus.
See more from Paramount Peptides
or learn how trust scores are computed on the
methodology page.