AI summary Trust: medium Third-party lab

LabD tested this CJC-1295 batch (V204086) at 81.77% purity via HPLC and mass quantification. The tested quantity was 1.73mg against a 2mg label, representing a 13.5% deviation. Endotoxin status is unknown. The test is older (6-12 months). Customers can cross-check on the lab's public verification URL.

Watch out for
  • low purity (81.77%)
  • quantity deviation (-13.5%)
  • no endotoxin test
Test date
2025-08-04
Purity
81.77% 81.77%
Batch / lot
V204086
Lab
LabD
Quantity
label 2mg tested 1.73mg
Qty vs label
-13.5%
Endotoxins
Test score
4.6
Manufacturer
Deuschem
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
2mg
Container
White Label / Silver Crimp / Blue Cap
Catalogued
2026-04-16
Artifact hash
d8353415217ef2a4…
This COA is part of TitrateLab's community-trust corpus. See more from Deuschem or learn how trust scores are computed on the methodology page.