AI summary Trust: medium Third-party lab

LabA tested this CJC-1295 batch (PRZ-CJC2) at 97.6% purity via HPLC. The tested quantity was significantly higher than the label at 5.98mg vs 5mg, a deviation of nearly 20%. Endotoxin status is unknown. This test is stale, over a year old. Customers can cross-check on the lab's public verification URL.

Watch out for
  • stale (1+ years old)
  • no endotoxin test
  • quantity deviation (19.6%)
Test date
2025-05-07
Purity
97.60% 97.60%
Batch / lot
PRZ-CJC2
Lab
LabA
Quantity
label 5mg tested 5.98mg
Qty vs label
+19.6%
Endotoxins
Test score
4.0
Manufacturer
Pure Rawz
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
5mg
Container
White Label / Silver Crimp / Yellow Cap
Catalogued
2026-04-16
Artifact hash
2867536926abd2a5…
This COA is part of TitrateLab's community-trust corpus. See more from Pure Rawz or learn how trust scores are computed on the methodology page.