AI summary
Trust: medium
Third-party lab
LabA tested this CJC-1295 batch (CJCD-080224) at 76.15% purity via HPLC. The tested quantity was significantly under the label at 3.46mg for a 5mg label (-30.8% deviation). Endotoxin status is unknown. This test is stale (over a year old). Customers can cross-check on the lab's public verification URL.
Watch out for
- low purity (76.15%)
- significant quantity deviation (-30.8%)
- no endotoxin test
Test date
2025-02-19
Purity
76.15%
76.15%
Batch / lot
CJCD-080224
Lab
LabA
Quantity
label
5mg
tested
3.46mg
Qty vs label
-30.8%
Endotoxins
—
Test score
3.6
Manufacturer
Planet Peptide
Certificate
Test report image
Certificate scan as published.
Source
Finnrick
✓ Artifact capturedWe have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.
Verify on upstream- Method
- HPLC + mass quantification + endotoxins
- Test type
- finnrick_composite
- Dose
- 5mg
- Container
- White Label / Silver Crimp / Red Cap
- Catalogued
- 2026-04-16
- Artifact hash
9fb29977be9780ba…
This COA is part of TitrateLab's community-trust corpus.
See more from Planet Peptide
or learn how trust scores are computed on the
methodology page.