AI summary Trust: medium Third-party lab

LabE tested this BPC-157 batch (01-007-PD) at 99.32% purity via HPLC. The tested quantity was significantly over-labeled at 12.6mg for a 10mg label (+26% deviation). Endotoxin status is unknown, and the test is older (6-12 months). Customers can cross-check on the lab's public verification URL.

Watch out for
  • no endotoxin test
  • stale (6-12 months)
  • quantity over-labeled (+26%)
Test date
2025-05-16
Purity
99.32% 99.32%
Batch / lot
01-007-PD
Lab
LabE
Quantity
label 10mg tested 12.6mg
Qty vs label
+26.0%
Endotoxins
Test score
5.6
Manufacturer
Peptidology
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
10mg
Container
White, Blue Label / Silver Crimp / Green Cap
Catalogued
2026-04-16
Artifact hash
ac46cf9726098a67…
This COA is part of TitrateLab's community-trust corpus. See more from Peptidology or learn how trust scores are computed on the methodology page.