AI summary
Trust: medium
Third-party lab
Janoshik tested this PT-141 from utherpeptide.com at 99.698% purity via HPLC + MS. The tested quantity of 13.62mg showed a significant 36.2% deviation from the 10mg label. The test is recent (under 3 months), and customers can cross-check on the lab's public verification URL, but endotoxin status is unknown.
Watch out for
- quantity deviation (36.2%)
- no endotoxin test
- batch ID unknown
Test date
2026-03-27
Purity
99.70%
99.698%
Batch / lot
—
Lab
Janoshik
Quantity
label
10mg
tested
13.62mg
Qty vs label
+36.2%
Endotoxins
—
Test score
—
Manufacturer
Uther Peptide
Source
Janoshik (public)
🔗 URL referencedThis entry references an upstream lab URL we crawled. We did not save the artifact, so we can't prove the report still loads as it did when we catalogued it.
Verify on upstream- Method
- HPLC + MS
- Dose
- 10mg
- Catalogued
- 2026-04-16
OCR text
Raw extracted text
OCR text
Raw extracted text
Extracted via OCR. Names, emails, phone numbers, and street addresses are auto-redacted before display.
{
"peptide": "PT-141",
"dose": "10mg",
"purity_pct": 99.698,
"purity_label": "99.698%",
"method": "",
"test_date": "2026-03-27",
"client": "utherpeptide.com",
"notes": "",
"label_qty": "10mg",
"tested_qty": "13.62mg",
"quantity_deviation_pct": 36.2,
"is_blend": false,
"components_json": "",
"ocr_confidence": 1.0
}
This COA is part of TitrateLab's community-trust corpus.