All BPC-157 Certificate of Analysis results— 2399 COAs
TitrateLab · Certificate of Analysis

BPC-157 99.5% Purity — crystalpeptides.euCertificate of Analysis · Independent third-party lab result

Tested purity 99.5% High purity · 99.502%
Dose vs label +6.2% Over the labeled dose
Evidence Artifact captured Trust: medium
AI summary Third-party lab

Janoshik tested this BPC-157 from crystalpeptides.eu at 99.502% purity via HPLC. The tested quantity of 5.31mg showed a 6.2% deviation from the 5mg label. The test is recent (3-6 months old), but the report does not include endotoxin testing. Customers can cross-check on the lab's public verification URL.

Watch out for
  • no endotoxin test
  • quantity deviation (6.2%)
Test date
2025-12-08
Testing lab
Janoshik
Batch / lot
Quantity
5.31mg
label 5mg · tested 5.31mg
Endotoxins
Assay method
HPLC
Label dose
5mg
Context

How this result compares

This BPC-157 certificate's tested purity of 99.50% ranks higher than 61% of the 2366 BPC-157 certificates with a purity result we have catalogued (median 99.36%).

Tested 2025-12-08 by Janoshik via HPLC. This test is newer than 41% of our catalogued BPC-157 certificates.

crystalpeptides.eu has 29 certificates in our corpus, including 3 for BPC-157 at a median tested purity of 99.50%.

Manufacturer
crystalpeptides.eu
View vendor profile
Peptides on this report
BPC-157
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Janoshik (public)

Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact shown here.

Verify on the upstream lab
Method
HPLC
Dose
5mg
Catalogued
2026-04-16
Artifact hash
2bbb987f00890334…
OCR text Raw extracted text

Extracted via OCR. Names, emails, phone numbers, and street addresses are auto-redacted before display.

{
  "peptide": "BPC-157",
  "dose": "5mg",
  "purity_pct": 99.502,
  "purity_label": "99.502%",
  "method": "",
  "test_date": "2025-12-08",
  "client": "[EMAIL_REDACTED]",
  "notes": "The peak with lambda [NAME_REDACTED] 270 nm was not counted among impurities.",
  "label_qty": "5mg",
  "tested_qty": "5.31mg",
  "quantity_deviation_pct": 6.2,
  "is_blend": false,
  "components_json": "",
  "ocr_confidence": 1.0
}
Related

Other BPC-157 certificates

All BPC-157 results & stats
This certificate is part of TitrateLab's community-trust corpus. See more from crystalpeptides.eu or learn how trust scores are computed on the methodology page. New to lab reports? How to read a COA →