AI summary Trust: medium Third-party lab

LabE tested this retatrutide at 99.81% purity via HPLC + mass quantification. The tested quantity was 9.11mg against a 10mg label, representing an 8.9% deviation. Endotoxin status is not applicable, and the test date is unknown, preventing an assessment of recency. Customers can cross-check on the lab's public verification URL.

Watch out for
  • no batch ID
  • unknown test date
  • quantity deviation (8.9%)
Test date
Purity
99.81% 99.81%
Batch / lot
(no batch ID)
Lab
LabE
Quantity
label 10mg tested 9.11mg
Qty vs label
-8.9%
Endotoxins
n/a
Test score
6.6
Manufacturer
Shanghai Sigma Audley Ssa
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
10mg
Container
No Label / Silver Crimp / White Cap
Catalogued
2026-04-16
Artifact hash
ccd26d1e013fe72a…
This COA is part of TitrateLab's community-trust corpus. See more from Shanghai Sigma Audley Ssa or learn how trust scores are computed on the methodology page.