Test date
2026-02-20
Purity
99.25% 99.248%
Batch / lot
013-PB-HJH
Lab
Peptide Test
Quantity
Qty vs label
Endotoxins
Test score
Manufacturer
Allen Biotechnology Co Abc
View vendor dossier
Source

abc_telegram

⚠ Asserted only
No verifiable evidence captured. This entry was added to our corpus from abc_telegram. We did not save the certificate image, did not hash an artifact, and the upstream URL is either a domain root or absent — we cannot independently confirm this report existed. Treat as curator-asserted only.
Dose
10mg
Catalogued
2026-05-26
OCR text

Raw extracted text

Extracted via OCR. Names, emails, phone numbers, and street addresses are auto-redacted before display.

6:42 POP ||||| 85
Certificate of Analysis
Peptide Test - powered by TrustPointe
Fast, Clear, Reliable Results
For Informed Decisions
www.peptidetest.com
Scan or Click to Verify
Verify at
TrustPointeLIMS.com
Key=LSBRU285BWFS
Publish Date: 2026-02-20
Client & Sample ID: STG ABC BPC DEC 2025 : 013-PB-
HJH
PEPTIDE TEST
Sample Name & Mfg: BPC-157 10mg 1 Vial ABC
PT
Photo of Sample:
Results
Sample ID
SPL-3053
TM-1006 BPC-157 Assay
11.11 mg
TM-1006 BPC-157 ID by RT
1.00
TM-1006 BPC-157 ID by Spectral
1000
TM-1006 BPC-157 Purity
99.248 %
TM-1006 BPC-157 Coelution Control
999
TM-1006 BPC-157 System Suit
0.6 %RSD
Not for Commercial Product Distribution Peptide Test provides consumer and group buy testing only. This COA is for private consumer
informational use and is not valid for businesses, medical clinics, or resellers to establish product quality, specifications, or suitability
for commercial distribution.
Created by
Reviewed by
A Just
Ashlee Lust
[NAME_REDACTED]
President
Managing Director
Page 1 of 2
Sample Assay: This is the amount of the compound in the vial we tested determined by HPLC analysis.
Sample Purity: This is purity of the sample, calculated including peaks around the compound that may be
Impurities.
ID by RT: This is an identification test in which the retention time of the sample is compared to the average
retention time of five reference standard injections.
ID by Spectral: This is an identification test in which the UV spectrum of the sample is compared to the UV
spectrum of the standard.
System Suitability: This value shows that the HPLC system was running properly throughout your testing. The
%RSD of the standard injections performed before your sample and the standard injection performed after your
sample is calculated to ensure there were no system errors during your run. Although system errors such as leaks,
a line running dry, air bubbles, etc. are rare, it's important that we demonstrate no errors occurred during analysis.
Coelution Control: NOTE: This value is not purity of the compound - the peak is pure compound as it was
separated out by the HPLC. This value demonstrates that there is no co-elution occurring during analysis. We
receive samples from a multitude of manufacturers and each has their own recipe (stabilizers, solubilizers, fillers,
excipients and ingredients, which are not tested for unless explicitly noted in the testing agreement and this Certificate of
Analysis (COA). The results provided do not imply suitability for any specific use or purpose, and testing is limited to the
measurement ensures that none of these other components interfere with the analysis. In short, this number confirms that
the method is working properly and only analyzing the target compound.
Important Testing Notice
The analytical results detailed herein pertain solely to the presence of the specified compounds in the samples as
submitted. These results are generated by our independent partner laboratory. It is acknowledged that all prepared
lyophilized peptide products and any other tested material may include stabilizers, solubilizers, fillers, and other
excipients and ingredients, which are not tested for unless explicitly noted in the testing agreement and this Certificate of
Analysis (COA). The results provided do not imply suitability for any specific use or purpose, and testing is limited to the
measurement ensures that none of these other components interfere with the analysis. In short, this number confirms that
the method is working properly and only analyzing the target compound. Clients and other users are advised that the
responsibility for determining the applicability of these results for any use rests entirely with them. It is imperative that any
users of this information consult with a physician prior to using any peptide or other compound. Peptides or other compounds
sold for "research purposes" may not be suitable for human use. Any liability for the provided analytical results is confined to the procedural...
This COA is part of TitrateLab's community-trust corpus. See more from Allen Biotechnology Co Abc or learn how trust scores are computed on the methodology page.