Test date
2026-02-20
Purity
99.25%
99.248%
Batch / lot
013-PB-HJH
Lab
Peptide Test
Quantity
—
Qty vs label
—
Endotoxins
—
Test score
—
Manufacturer
Allen Biotechnology Co Abc
Source
abc_telegram
⚠ Asserted only
No verifiable evidence captured.
This entry was added to our corpus from abc_telegram.
We did not save the certificate image, did not hash an artifact,
and the upstream URL is either
a domain root or absent — we cannot independently confirm this report existed. Treat
as curator-asserted only.
- Dose
- 10mg
- Catalogued
- 2026-05-26
OCR text
Raw extracted text
OCR text
Raw extracted text
Extracted via OCR. Names, emails, phone numbers, and street addresses are auto-redacted before display.
6:42 POP ||||| 85 Certificate of Analysis Peptide Test - powered by TrustPointe Fast, Clear, Reliable Results For Informed Decisions www.peptidetest.com Scan or Click to Verify Verify at TrustPointeLIMS.com Key=LSBRU285BWFS Publish Date: 2026-02-20 Client & Sample ID: STG ABC BPC DEC 2025 : 013-PB- HJH PEPTIDE TEST Sample Name & Mfg: BPC-157 10mg 1 Vial ABC PT Photo of Sample: Results Sample ID SPL-3053 TM-1006 BPC-157 Assay 11.11 mg TM-1006 BPC-157 ID by RT 1.00 TM-1006 BPC-157 ID by Spectral 1000 TM-1006 BPC-157 Purity 99.248 % TM-1006 BPC-157 Coelution Control 999 TM-1006 BPC-157 System Suit 0.6 %RSD Not for Commercial Product Distribution Peptide Test provides consumer and group buy testing only. This COA is for private consumer informational use and is not valid for businesses, medical clinics, or resellers to establish product quality, specifications, or suitability for commercial distribution. Created by Reviewed by A Just Ashlee Lust [NAME_REDACTED] President Managing Director Page 1 of 2 Sample Assay: This is the amount of the compound in the vial we tested determined by HPLC analysis. Sample Purity: This is purity of the sample, calculated including peaks around the compound that may be Impurities. ID by RT: This is an identification test in which the retention time of the sample is compared to the average retention time of five reference standard injections. ID by Spectral: This is an identification test in which the UV spectrum of the sample is compared to the UV spectrum of the standard. System Suitability: This value shows that the HPLC system was running properly throughout your testing. The %RSD of the standard injections performed before your sample and the standard injection performed after your sample is calculated to ensure there were no system errors during your run. Although system errors such as leaks, a line running dry, air bubbles, etc. are rare, it's important that we demonstrate no errors occurred during analysis. Coelution Control: NOTE: This value is not purity of the compound - the peak is pure compound as it was separated out by the HPLC. This value demonstrates that there is no co-elution occurring during analysis. We receive samples from a multitude of manufacturers and each has their own recipe (stabilizers, solubilizers, fillers, excipients and ingredients, which are not tested for unless explicitly noted in the testing agreement and this Certificate of Analysis (COA). The results provided do not imply suitability for any specific use or purpose, and testing is limited to the measurement ensures that none of these other components interfere with the analysis. In short, this number confirms that the method is working properly and only analyzing the target compound. Important Testing Notice The analytical results detailed herein pertain solely to the presence of the specified compounds in the samples as submitted. These results are generated by our independent partner laboratory. It is acknowledged that all prepared lyophilized peptide products and any other tested material may include stabilizers, solubilizers, fillers, and other excipients and ingredients, which are not tested for unless explicitly noted in the testing agreement and this Certificate of Analysis (COA). The results provided do not imply suitability for any specific use or purpose, and testing is limited to the measurement ensures that none of these other components interfere with the analysis. In short, this number confirms that the method is working properly and only analyzing the target compound. Clients and other users are advised that the responsibility for determining the applicability of these results for any use rests entirely with them. It is imperative that any users of this information consult with a physician prior to using any peptide or other compound. Peptides or other compounds sold for "research purposes" may not be suitable for human use. Any liability for the provided analytical results is confined to the procedural...
This COA is part of TitrateLab's community-trust corpus.
See more from Allen Biotechnology Co Abc
or learn how trust scores are computed on the
methodology page.