AI summary Trust: medium Third-party lab

LabE tested this BPC-157 batch at 99.9% purity using HPLC and mass quantification. However, the tested quantity was significantly under-dosed at 4.63mg against a 10mg label, representing a -53.7% deviation. Endotoxin status is not applicable, and the test is recent (under 3 months).

Watch out for
  • major quantity deviation (-53.7%)
  • no endotoxin test
  • no batch ID
Test date
2026-04-28
Purity
99.90% 99.90%
Batch / lot
(no batch ID)
Lab
LabE
Quantity
label 10mg tested 4.63mg
Qty vs label
-53.7%
Endotoxins
n/a
Test score
4.6
Manufacturer
Tianjin Ruiwang New Material Technology Co
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
10mg
Container
No Label / Silver Crimp / Yellow Cap
Catalogued
2026-05-02
Artifact hash
b51868a690f10906…
This COA is part of TitrateLab's community-trust corpus. See more from Tianjin Ruiwang New Material Technology Co or learn how trust scores are computed on the methodology page.