Evidence archive · record 79812
TB-500 certificate,
identity under review.
A real, dated lab record with its reported measurements visible. Pro opens the original document, verification trail and surrounding batch history.
Public evidence summaryActual record data · not an example
VendorVendor pending verification
CompoundTB-500
Test date2025-08-13
Testing labChromate
Source archivechromate_public
Batch IDAW0183-1-2
Laboratory measurements
What the lab reported
These values are transcribed from the named certificate. They are evidence from one submitted sample, not a guarantee about every vial from a vendor.
Reported laboratory resultsChecked 2026-08-15
PurityChemical purity reported on the certificate
99.57%
Measured quantityQuantity reported by the testing lab
4.103mg
Label claimQuantity stated on the submitted label
5mg
Difference from labelMeasured quantity compared with the label claim
-17.94%
Record note: TB-500 batch AW0183-1-2 exceeds purity spec at 99.57%, but underfilled by ~18% (4.1mg vs 5mg nominal). RP-HPLC confirmed identity.
Pro evidence trail: open the original certificate, upstream verification link, related records and vendor history.