AI summary Trust: medium Third-party lab

LabE tested this Tesamorelin batch (TS25-01) at 48.94% purity via HPLC. The tested quantity was significantly under-dosed at 3.66mg against a 10mg label, representing a -63.4% deviation. Endotoxin status is unknown. The test is older (6-12 months) but customers can cross-check on the lab's public verification URL.

Watch out for
  • significant quantity deviation
  • no endotoxin test
  • older (6-12 months)
Test date
2025-06-29
Purity
48.94% 48.94%
Batch / lot
TS25-01
Lab
LabE
Quantity
label 10mg tested 3.66mg
Qty vs label
-63.4%
Endotoxins
Test score
3.0
Manufacturer
Regenerative Research
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
10mg
Container
White Label / Silver Crimp / Black Cap
Catalogued
2026-04-16
Artifact hash
a7363e7538f6c535…
This COA is part of TitrateLab's community-trust corpus. See more from Regenerative Research or learn how trust scores are computed on the methodology page.