AI summary Trust: medium Third-party lab

LabA tested this Tesamorelin at 99.04% purity via HPLC and mass quantification. However, the tested quantity was significantly under-dosed at 7.25mg against a 10mg label (-27.5% deviation). Endotoxin status is unknown, and the test is older (6-12 months). Customers can cross-check on the lab's public verification URL.

Watch out for
  • significant quantity deviation
  • no endotoxin test
  • older (6-12 months)
Test date
2025-06-27
Purity
99.04% 99.04%
Batch / lot
(no batch ID)
Lab
LabA
Quantity
label 10mg tested 7.25mg
Qty vs label
-27.5%
Endotoxins
Test score
3.0
Manufacturer
Sry Labs
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
10mg
Container
White Label / Silver Crimp / Green Cap
Catalogued
2026-04-16
Artifact hash
28ff75e04daf85d1…
This COA is part of TitrateLab's community-trust corpus. See more from Sry Labs or learn how trust scores are computed on the methodology page.