All PT-141 Certificate of Analysis results— 625 COAs
TitrateLab · Certificate of Analysis

PT-141 99.9% Purity — Polaris PeptidesCertificate of Analysis · Independent third-party lab result

Tested purity 99.9% High purity · 99.88%
Dose vs label +13.0% Over the labeled dose -2.7% vs vendor claim
Evidence Artifact captured Trust: medium
AI summary Third-party lab

LabE tested this PT-141 batch (POL-PT14110-4) at 99.88% purity via HPLC and mass quantification. Quantity was 11.3mg against a 10mg label, a -2.7% deviation. Endotoxin status is not available. The test is older (6-12 months). Customers can cross-check on the lab's public verification URL.

Watch out for
  • no endotoxin test
  • older (6-12 months)
Test date
2025-08-11
Testing lab
LabE
Batch / lot
POL-PT14110-4
Quantity
11.3mg
label 10mg · tested 11.3mg
Endotoxins
Assay method
HPLC + mass quantification + endotoxins
Test score
9.0
Label dose
10mg
Context

How this result compares

This PT-141 certificate's tested purity of 99.88% ranks higher than 47% of the 624 PT-141 certificates with a purity result we have catalogued (median 99.89%).

Tested 2025-08-11 by LabE via HPLC + mass quantification + endotoxins. This test is newer than 18% of our catalogued PT-141 certificates.

Polaris Peptides has 150 certificates in our corpus, including 10 for PT-141 at a median tested purity of 99.86%.

Manufacturer
Polaris Peptides
View vendor profile
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact shown here.

Verify on the upstream lab
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
10mg
Container
Black Label / Blue Crimp / Clear Cap
Catalogued
2026-04-16
Artifact hash
34c3cb60071e5470…
Saved source

Saved source document

sha256:cdeafb79a312d223… — immutable copy held by TitrateLab

Related

Other PT-141 certificates

All PT-141 results & stats
This certificate is part of TitrateLab's community-trust corpus. See more from Polaris Peptides or learn how trust scores are computed on the methodology page. New to lab reports? How to read a COA →