AI summary Trust: medium Third-party lab

LabG tested this PT-141 batch (VI1420241021-10) at 100.0% purity via HPLC + mass quantification. The tested quantity was 22% higher than the 10mg label, and endotoxin status is unknown. The test is older (6-12 months). Customers can cross-check on the lab's public verification URL.

Watch out for
  • no endotoxin test
  • stale (6-12 months)
  • quantity deviation (22%)
Test date
2025-08-12
Purity
100.00% 100.00%
Batch / lot
VI[PHONE_REDACTED]-10
Lab
LabG
Quantity
label 10mg tested 12.2mg
Qty vs label
+22.0%
Endotoxins
Test score
7.0
Manufacturer
Peptide Sciences
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
10mg
Container
White Label / Silver Crimp / Purple Cap
Catalogued
2026-04-16
Artifact hash
508660c31a33f847…