AI summary Trust: medium Third-party lab

LabA tested this Ipamorelin at 98.53% purity via HPLC and mass quantification. However, the quantity tested was significantly under-dosed at 3.51mg against a 5mg label (-29.8% deviation). Endotoxin status is unknown, and the test is stale (over 1 year old).

Watch out for
  • significant quantity deviation
  • no endotoxin test
  • stale (1+ years old)
Test date
2025-03-20
Purity
98.53% 98.53%
Batch / lot
(no batch ID)
Lab
LabA
Quantity
label 5mg tested 3.51mg
Qty vs label
-29.8%
Endotoxins
Test score
2.4
Manufacturer
Peptide Gurus
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
5mg
Container
Black & White Label / Copper Crimp / Clear Cap
Catalogued
2026-04-16
Artifact hash
b771bdda406b1d79…
This COA is part of TitrateLab's community-trust corpus. See more from Peptide Gurus or learn how trust scores are computed on the methodology page.