AI summary Trust: medium Third-party lab

LabD tested this Ipamorelin at 99.85% purity using HPLC and mass quantification. The tested quantity was 5.91mg against a 5mg label, showing an 18.2% deviation. Endotoxin status is unknown, and the test is stale (over 1 year old). Customers can cross-check on the lab's public verification URL.

Watch out for
  • stale (1+ years old)
  • no endotoxin test
  • quantity deviation (18.2%)
Test date
2025-04-22
Purity
99.85% 99.85%
Batch / lot
(no batch ID)
Lab
LabD
Quantity
label 5mg tested 5.91mg
Qty vs label
+18.2%
Endotoxins
Test score
5.1
Manufacturer
Platinum Cryo
View vendor dossier
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Finnrick

✓ Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.

Verify on upstream
Method
HPLC + mass quantification + endotoxins
Test type
finnrick_composite
Dose
5mg
Container
White Label / Silver Crimp / Blue Cap
Catalogued
2026-04-16
Artifact hash
db4dc57b2e7d73a1…
This COA is part of TitrateLab's community-trust corpus. See more from Platinum Cryo or learn how trust scores are computed on the methodology page.