Test date
—
Purity
—
Batch / lot
mp49rhf
Lab
Finnrick
Quantity
—
Qty vs label
—
Endotoxins
—
Test score
—
Manufacturer
Allen Biotechnology Co Abc
Source
abc_telegram
⚠ Asserted only
No verifiable evidence captured.
This entry was added to our corpus from abc_telegram.
We did not save the certificate image, did not hash an artifact,
and the upstream URL is either
a domain root or absent — we cannot independently confirm this report existed. Treat
as curator-asserted only.
- Catalogued
- 2026-06-12
OCR text
Raw extracted text
OCR text
Raw extracted text
Extracted via OCR. Names, emails, phone numbers, and street addresses are auto-redacted before display.
7:59 3 of 3 m/[NAME_REDACTED] 201370 47 (0.869) 100- [PHONE_REDACTED] 900 1000 Tirzepatide 30 (0.555) 100- 968 [PHONE_REDACTED] 1116 1144 1100 1216 1205 1200 1217 1279 1300 1322 1410 1400 1216 1201 1100 1217 1200 1303 1300 1323 1400 1474 1500 1482 1500 1614 1606 1621 1600 1613 1606 1628 1600 1700 1713 1797 1807 1863 1886 1800 m/z Scan ES+ 4.08e5 1700 1713 1796 1807 1863 1896 1800 m/z Scan ES+ 4.14e5 Krause Analytical, LLC [ADDRESS_REDACTED] B-206 Austin, TX 78759 [EMAIL_REDACTED] Finnrick Testing Certificate © 2026 Finnrick Analytics LLC and its suppliers, all rights reserved. Unauthorized distribution and modification prohibited. FINNRICK krause analytical Finnrick Testing Certificate Test Certificate ID: mp49rhf Verify at https://finnrick.com/verify Page 3 of 3 Methods Summary Purity/Potency/Identification • • • • • • USP/NF 621 2 mL of purified water is added to the lyophilized powder in the vial, and the contents mixed to dissolve the lyophilized powder. An aliquot is taken from the vial and diluted to contain approximately 500 mg/L of the peptide. The diluted sample is analyzed by HPLC-UV-MS. The mass spectrum obtained is compared to an authentic standard of the peptide for identification. The total area of all of the peaks in the chromatogram is calculated, and the area of the peak of the peptide is divided by the total area to obtain the chromatographic purity value, reported in percent. The area of the peptide is compared to the area of the peptide peak in the known standard to obtain a concentration in the solution. This concentration is used to calculate the total mass of peptide in the vial, which is compared to the stated mass (label claim) and reported as both total mass in the vial and as a percent of the label claim. Endotoxins • • • USP/NF 85 2 mL of purified water is added to the lyophilized powder in the vial, and the contents mixed to dissolve the lyophilized powder. An aliquot is taken from the vial and diluted in endotoxin-free water. The diluted sample is analyzed for endotoxins using the LAL method. Metals • • • USP/NF 233 2 mL of purified water is added to the lyophilized powder in the vial, and the contents mixed to dissolve the lyophilized powder. An aliquot is taken from the vial and diluted in deionized water. The diluted aliquot is analyzed against known standards by ICP-MS Krause Analytical, LLC [ADDRESS_REDACTED] B-206 Austin, TX 78759 Finnrick Testing Certificate © 2026 Finnrick Analytics LLC and its suppliers, all rights reserved. Unauthorized distribution and modification prohibited. finnrick.com
This COA is part of TitrateLab's community-trust corpus.
See more from Allen Biotechnology Co Abc
or learn how trust scores are computed on the
methodology page.