All Tirzepatide Certificate of Analysis results— 7380 COAs
TitrateLab · Certificate of Analysis

Tirzepatide 99.5% Purity — LowBatteryCertificate of Analysis · Independent third-party lab result

Tested purity 99.5% High purity · 99.5280%
Dose vs label +13.1% Over the labeled dose
Evidence Artifact captured Trust: low
AI summary Third-party lab

Janoshik tested this tirzepatide COA, showing 99.528% purity via HPLC. The tested quantity was 16.96mg against a 15mg label, a deviation of +13.07%. However, the report notes that a different peptide (retatrutide) was detected in vial A instead of tirzepatide. The test is stale (over 1 year old). Customers can cross-check on the lab's public verification URL.

Watch out for
  • stale (1+ years old)
  • no endotoxin test
  • different peptide detected
Test date
2025-04-16
Testing lab
Janoshik
Batch / lot
Quantity
16.96mg
label 15mg · tested 16.96mg
Endotoxins
Assay method
HPLC
Label dose
15mg
Context

How this result compares

This Tirzepatide certificate's tested purity of 99.53% ranks higher than 14% of the 7378 Tirzepatide certificates with a purity result we have catalogued (median 99.82%).

Tested 2025-04-16 by Janoshik via HPLC. This test is newer than 12% of our catalogued Tirzepatide certificates.

Manufacturer
LowBattery
Certificate

Test report image

Certificate scan
Certificate scan as published.
Source

Janoshik (public)

Artifact captured

We have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact shown here.

Verify on the upstream lab
Method
HPLC
Dose
15mg
Catalogued
2026-04-24
Artifact hash
1e7e0b84beda029d…
OCR text Raw extracted text

Extracted via OCR. Names, emails, phone numbers, and street addresses are auto-redacted before display.

{"peptide": "Tirzepatide", "dose": "15mg", "purity_pct": 99.528, "purity_label": "99.5280%", "method": "HPLC", "test_date": "2025-04-16", "client": "LowBattery", "notes": "Different peptide detected in vial A \u2013 retatrutide. Tirzepaptide not detected as expected; only 16.96 mg measured instead of labeled 15mg, but with high purity of detected compound.", "label_qty": "15mg", "tested_qty": "16.96mg", "quantity_deviation_pct": 13.07, "is_blend": false, "components_json": "", "ocr_confidence": 0.92}
Related

Other Tirzepatide certificates

All Tirzepatide results & stats
This certificate is part of TitrateLab's community-trust corpus. See more from LowBattery or learn how trust scores are computed on the methodology page. New to lab reports? How to read a COA →